框架柱斜截面配筋计算层数B轴框架柱斜截面配筋计算一层二层三层四层五层六层七层N/kN2392212916801308910624313V/kN114.35126.01118.0197.0677.5055.1350.00Hn(m)3.95333333λ=Hn/(2h0)3.532.682.682.682.682.682.68λ(>3时取3)3.002.682.682.682.682.682.681029.61029.61029.61029.61029.61029.61029.6截面是否满足满足满足满足满足满
框架柱斜截面配筋计算.doc
框架柱斜截面配筋计算层数B轴框架柱斜截面配筋计算一层二层三层四层五层六层七层N/kN2392212916801308910624313V/kN114.35126.01118.0197.0677.5055.1350.00Hn(m)3.95333333λ=Hn/(2h0)3.532.682.682.682.682.682.68λ(>3时取3)3.002.682.682.682.682.682.681029.61029.61029.61029.61029.61029.61029.6截面是否满足满足满足满足满足满
框架柱斜截面配筋计算.doc
框架柱斜截面配筋计算层数B轴框架柱斜截面配筋计算一层二层三层四层五层六层七层N/kN2392212916801308910624313V/kN114.35126.01118.0197.0677.5055.1350.00Hn(m)3.95333333λ=Hn/(2h0)3.532.682.682.682.682.682.68λ(>3时取3)3.002.682.682.682.682.682.681029.61029.61029.61029.61029.61029.61029.6截面是否满足满足满足满足满足满
柱斜截面配筋.docx
框架柱的斜截面配筋设计。在大(小)偏心受压情况下框架柱的斜截面受剪承载力计算公式如下所示:经过计算如果,那么就可以忽略柱子斜截面受剪承载力的计算,只需要依照构造要求配设箍筋。下面将在(大)偏心受压情况下,柱子斜截面受剪承载力的计算和配筋设计整理成表格。首层框架柱斜截面受剪承载力计算及配筋表构件截面设计值首层边柱首层中柱柱上截面6柱下截面7柱上截面6柱下截面7弯矩Mc(KN·M)177.85(抗震)89.42(非抗震)162.55(抗震)82.18(非抗震)241.91(抗震)92.83(非抗震)233.8
框架柱的配筋计算.docx
框架柱的配筋计算选取第一层柱进行计算和配筋:1.柱的正截面承载力计算柱的配筋采用对称式(以利于不同方向的地震作用),为便于施工,柱子纵向钢筋绑扎接头,应避开箍筋加密区。搭接、锚固及截断见混凝土结构施工整体平面整体表示方法制图规则和构造详图,03G101—1。柱截面尺寸为,,。(1)确定钢筋和混凝土的材料强度及几何参数采用混凝土,,,采用级钢筋,,,,。a.A轴线外柱查柱组合表可以知道A轴线外柱,。(2)判断大小偏心受压,截面破坏时为大偏心受压破坏。原始偏心距附加偏心距,取初始偏心距,取,取底层框架柱的计算